Welcome, Guest
Other Articles
- 10 Questions to Ask Before A Lighting Upgrade
- 2 Steps Towards Better Lighting
- 3 Reasons to Recycle Spent Lamps
- 5 Facts FMs Should Know About New Lighting Regulations
- 5 ROI-Generating Winter Facility Improvements
- A Case for Fluorescent Lamp Recycling
- A New Look at Lamp Disposal
- A new Pennsylvania law, in effect as of Jan. 24, 2013, bans e-waste from landfills.
- A Snapshot of Small Facility Lamp Recycling
- Air Cycle at U.S. Green Building Council Heartland Regional Conference
- Air Cycle Sponsors & Participates in Sustainable Saturday Recycling Event
- Are Lighting Retrofits Worth the Money?
- Break a Bulb? EPA Safety Tips Can Keep You and Your Workplace Safe
- Bulb Recycling, Step by Step
- California Law Requires Fluorescent Lamp Recycling
- CFL Bulb Recycling Options Abound
- Cleaning Your Fluorescent Lights
- Colorado Enacts New E-Waste Law
- Congress Delays Incandescent Light Bulb Ban
- Customize Lighting Controls with Wireless Flexibility
- Daylighting: Obstacle or Opportunity?
- Efficiency, Avoiding Mistakes Key To Lighting Retrofits
- EPA 2010 Enforcement and Compliance Results
- EPA Reports Record Fine Levels for 2010
- EPA Updates CFL Cleanup and PCB Exposure Guidance
- Everyday Protocols to Reduce Environmental Impact
- Fluorescent and HID Lamp Troubleshooting Guide
- Fluorescent Lamp and Controls Myths
- Fluorescent Lamp Recycling: The "Green" Litmus Test
- Fluorescent Lighting Design Tips
- Fluorescent Magnetic T12 Ballast: RIP
- Fluorescent Magnetic T12 Ballast: RIP
- Getting Started On Upgrades To Older Lighting Systems
- Gmail Instructions
- Good Riddance to Old Fluorescent Lamps
- Hazmat Management: A Nine-Step Program
- High Rise Facilities' Waste Recycling Solutions
- Hines' Corporate Office Awarded LEED Platinum
- How to Survive an OSHA Audit
- Illinois Expands E-Waste Recycling Law
- Improve LEED Score and Building Efficiency
- Innovative Fluorescent Bulb Recycling Plan "Brewing" at Teavana
- Introducing VaporShield®
- Is Outsourcing Right For Your Facility?
- Lamp Recycling Made Easy - Universal Waste Rule Compliance
- Lamp Recycling Now Required in Washington
- Lamp Recycling: The Easy Way to Go Green
- LampRecycling.com Articles
- Lighting 101: Key Principles
- Lighting 101: Key Principles
- Lighting Controls: Luxury or Necessity?
- Lighting Upgrade: Energy and Financial Savings
- Macy's Settles with EPA for Lamp Violations
- Making a building go green doesn't have to mean making big structural changes. Here are 5 ways to do it simply.
- Managing Hazardous Materials in E-Waste
- Marriott Hotels Recycle Lamps, Universal Waste With EasyPak
- Maryland School District Streamlines Lighting Systems for Savings
- Massachusetts Fluorescent Lamp Recycling Facts
- Meet Air Cycle at A&WMA Conference in June
- Minimizing Lamp and Ballast Recycling Costs
- Navigating OSHA's New Reporting Requirements
- New 2010 E-Waste Recycling Laws
- New E-Waste Policy For Federal Government
- New Fluorescent Lamp Ballast Standards
- New NY Rechargeable Battery Recycling Law
- New State E-Waste Regulations
- New State E-Waste Regulations Update
- New Study Shows Mercury in Fish Widespread
- New York Law to Require E-Waste Recycling
- Newsweek has ranked CBRE Group, Inc. the greenest real estate company in its 2011 Green Rankings. The list measures the environmental performance of the 500 largest U.S.-based publicly traded companies.
- Operating Lamps in Winter Conditions
- Organized MRO Storerooms Improve Productivity, Operations
- Planning for Lighting Controls
- Prevent 17 Common Fluorescent Lighting Mistakes
- Proper Lamp Disposal Necessary to Avoid Fines
- Reasons to Consider Recycling Spent Fluorescent Lamps
- Recycling Bulbs and Sustainability for Facility Managers
- Recycling Fluorescent Lamps: It Can Be Affordable and Easy
- Recycling Roundtable: Three FMs Weigh In
- Rise to the Challenge: Three High-Rise Owners Turn Obstacles into Opportunities
- Safety, Savings Achieved With Emergency Lighting System Upgrades
- Strategic Tips For Ensuring Year-Round Earth Day Benefits
- Strategies to Plan for T12 Lamp Phase-Out
- Successful Recycling: A Three-Step Approach
- Successful Recycling: Achieving Sustainability Goals
- Sustainability: The Great Differentiator
- T12 Lamp Phase-Out: Managing the Change
- The Hidden Benefits of Lamp Recycling
- The Hidden Financial Benefits of Fluorescent Lamp Upgrading
- The Other Environmental Contaminant
- The Road to Fluorescent Lamp Recycling: A 10-Step Guide
- Tripling Down On The Bottom Line: Facility Management Strategies
- U.S. Launches National Strategy for Electronics Stewardship
- Using Metrics to Optimize Light Quality and Efficiency
- What Are the Best Fluorescent Bulb Disposal Options?
- What Not To Do With Fluorescent Lamps
- What to Do With All Those Old PCs
- What’s the Future Of Green Buildings In 2014? Industry Leader Offers Top 10 Megatrends
- When To Turn Off Your Fluorescent Lights
- Why Bulb Recycling Works
- Why Fluorescent Lamp Recycling Still Matters
Break a Bulb? EPA Safety Tips Can Keep You and Your Workplace Safe
Because CFLs contain a small amount of mercury, EPA recommends the following clean-up and disposal guidelines:
1. Before Clean-up: Ventilate the Room
- Have people and pets leave the room, and don't let anyone walk through the breakage area on their way out.
- Open a window and leave the room for 15 minutes or more.
- Shut off the central forced-air heating/air conditioning system, if you have one.
2. Clean-Up Steps for Hard Surfaces
- Carefully scoop up glass fragments and powder using stiff paper or cardboard and place them in a glass jar with metal lid (such as a canning jar) or in a sealed plastic bag.
- Use sticky tape, such as duct tape, to pick up any remaining small glass fragments and powder.
- Wipe the area clean with damp paper towels or disposable wet wipes and place them in the glass jar or plastic bag.
- Do not use a vacuum or broom to clean up the broken bulb on hard surfaces.
3. Clean-up Steps for Carpeting or Rug:
- Carefully pick up glass fragments and place them in a glass jar with metal lid (such as a canning jar) or in a sealed plastic bag.
- Use sticky tape, such as duct tape, to pick up any remaining small glass fragments and powder.
- If vacuuming is needed after all visible materials are removed, vacuum the area where the bulb was broken.
- Remove the vacuum bag (or empty and wipe the canister), and put the bag or vacuum debris in a sealed plastic bag.
4. Clean-up Steps for Clothing, Bedding, etc.:
- If clothing or bedding materials come in direct contact with broken glass or mercury-containing powder from inside the bulb that may stick to the fabric, the clothing or bedding should be discarded. Do not wash such clothing or bedding because mercury fragments in the clothing may contaminate the machine and/or pollute sewage.
- You can, however, wash clothing or other materials that have been exposed to the mercury vapor from a broken CFL, such as the clothing you happened to be wearing when you cleaned up the broken CFL, as long as that clothing has not come into direct contact with the materials from the broken bulb.
- If shoes come into direct contact with broken glass or mercury-containing powder from the bulb, wipe them off with damp paper towels or disposable wet wipes. Place the towels or wipes in a glass jar or plastic bag for disposal.
5. Disposal of Clean-up Materials
- Immediately place all cleanup materials outdoors in a trash container or protected area for the next normal trash pickup.
- Wash your hands after disposing of the jars or plastic bags containing clean-up materials.
- Check with your local or state government about disposal requirements in your specific area. Some states prohibit such trash disposal and require that broken and unbroken mercury-containing bulbs be taken to a local recycling center.
6. Future Cleaning of Carpeting or Rug: Ventilate the Room During and After Vacuuming
- The next several times you vacuum, shut off the central forced-air heating/air conditioning system and open a window prior to vacuuming.
- Keep the central heating/air conditioning system shut off and the window open for at least 15 minutes after vacuuming is completed.